Highlights: • ICF-Therm is an Insulated Concrete Formwork system used in the construction and insulation of external and internal loadbearing walls in both residential and commercial buildings.

The ICF-Therm system consists of two opposing insulation panels moulded from high density expanded polystyrene, the panels are spaced apart using high strength polypropylene webs to form straight and 90° corner ICF blocks.

To enhance the systems thermal performance, header and cavity closer panels are inserted around window and door openings. During ICF wall assembly steel reinforcement is fixed in specified locations and the wall temporarily braced. Readymix concrete is then placed into the ICF-Therm wall to deliver a super strong and air-tight insulated structure.

The ICF-Therm system is available in three wall U-value options each with either a 150mm or 200mm concrete core thickness.

Technical data External / Internal corner block
   
External ICF panel average thickness* 78 mm
Internal ICF panel average thickness* 78 mm
Max block length (external)** 1287mm
Max block length (internal)** 663mm
Max block height (interlocked) 400 mm
Max block height including lugs (not interlocked) 428 mm
   
Max ICF wall width (inner panel + concrete core + outer panel) 312 mm
Max concrete core width (Including castellations) 162 mm
Min concrete core width (Excluding castellations) 150 mm
M² of external corner wall area / block (interlocked) 0.51 m²
Number of interlocked ICF corner blocks / m² of wall (external) 1.94
   
Concrete volume / corner block .059 m³
Concrete volume / m² of external corner blocks .112 m³
Avg. moulding density of EPS 24-25 kg/m³
Avg. Weight / 310 ICF external/internal corner block 2.37 kg
Avg. weight / m² of wall of 310 ICF external/internal corner blocks 4.59 kg
   
Avg. corner blocks / pallet (varies) 15 / 18
Avg. external wall m² / pallet (varies) 7.65 m² / 9.18 m²
Avg. product weight / pallet (varies) 35.5 kg / 42.6 kg
Nominal thermal conductivity / unit (W/mk) 0.031
Nominal U value (W/m²k) *** 0.19
   
Min compressive strength 125 kPA
Min flexural strength 170 kPA
Reaction to fire Euro Class E
Panel top and bottom joint design Interlocking
Panel side joint design Butted
   
ICF external corner block design option Fixed block only
Panel composition Flame retardent expanded polystyrene
Web tie composition Recycled polypropylene
Panel outer surface design Horizontal and vertical line pattern
Panel inner surface design Raised castellations designed to receive header and cavity closers parts
Uses **** Suitable for internal and external loadbearing wall applications above and below ground.
 