360/150 Straight ICF block (Grey)

Highlights: • ICF-Therm is an Insulated Concrete Formwork system used in the construction and insulation of both external and internal loadbearing walls in residential and commercial buildings.

The ICF-Therm system consists of two opposing insulation panels moulded from high density expanded polystyrene, the panels are spaced apart using high strength polypropylene webs to form straight and 90° corner ICF blocks. To enhance the systems thermal performance, header and cavity closer panels are inserted around window and door openings. During ICF wall assembly steel reinforcement is fixed in specified locations and the wall temporarily braced. Readymix concrete is then placed into the ICF-Therm wall to deliver a super strong and air-tight insulated structure. The ICF-Therm system is available in three wall U-value options each with either a 150mm or 200mm concrete core thickness.

Technical data Straight block
   
External ICF panel average thickness* 128 mm
Internal ICF panel average thickness* 78 mm
Max block length ** 1200 mm
Max block height (interlocked) 400 mm
Max block height including lugs (not interlocked) 428 mm
   
Max ICF wall width (inner panel + concrete core + outer panel) 362 mm
Max concrete core width (Including castellations) 162 mm
Min concrete core width (Excluding castellations) 150 mm
M² of wall area / block (interlocked) 0.48 m²
Number of interlocked ICF straight blocks / m² of wall 2.083
   
Concrete volume / straight block .074 m³
Concrete volume / m² of ICF straight block wall .154 m³
Avg. moulding density of EPS 24-25 kg/m³
Avg. Weight / ICF straight block 3.7 kg
Avg. weight of ICF straight blocks / m2 of wall 7.7 kg
   
Avg. straight blocks / pallet (varies) 18 / 21
Avg. wall m2 / pallet (varies) 8.64 m² / 10.08 m²
Avg. product weight / pallet (varies) 66.6 kg / 77.7 kg
Nominal thermal conductivity / unit (W/mk) 0.031
Nominal U value (W/m²k) *** 0.15
   
Min compressive strength 125 kPA
Min flexural strength 170 kPA
Reaction to fire Euro Class E
Panel top and bottom joint design Interlocking
Panel side joint design Butted
   
ICF straight block assembly options (1) Fixed block (2) Independent block: ICF panels are assembled on-site to form a block.
Panel composition Flame retardent expanded polystyrene
Web tie composition Recycled polypropylene
Panel outer surface design Horizontal and vertical line pattern
Panel inner surface design Raised castellations designed to receive header and cavity closers parts
Uses **** Suitable for internal and external loadbearing wall applications above and below ground.
 